Product overview

The pump body is made of PP/PVDF engineering plastic injection molding, which can resist strong acid and alkali and can run idling. The motor shaft adopts SUS304 stainless steel shaft, and the motor shaft adopts high-speed butt welding shaft process to ensure the service strength of the long shaft. The pump head assembly is completely molded, standardized, easy to disassemble and assemble, and easy to maintain. Suitable for all kinds of acid and alkali circulation, cooling, spray cleaning equipment, waste gas tower, etching, electrophoretic coating, waste water treatment, etc.

Model Description

Schematic diagram of structure

Product installation and precautions:

 

1. This pump has no shaft seal pump. When the liquid level rises to the vicinity of the flange surface of the pump motor, liquid leakage will occur above the pump. Therefore, please refer to the following setting examples when installing the pump.

2. When air is trapped in the front cover and suction pipe, the pump will not be able to lift water. In order not to accumulate air, the raised pipe should be avoided to prevent air locking (idling).

3. When conveying the mixed liquid of particles, a filter screen should be installed.

4. When setting in the groove, depending on the liquid medicine, the front cover should use PPS material and other screws.

5. Excessive locking of pump flange surface is strictly prohibited.

A. piping and pump flange surface should be parallel, and avoid excessive screw locking.

B. When flexible connecting pipes or SUS movable flanges and inner gaskets are used on the piping side, over-tightening screws shall be avoided, resulting in deformation of the pump flange.

6. Piping load is strictly prohibited.

a. Fully support the piping weight with the bracket.

B. high temperature (40 ℃), should consider the piping thermal expansion, without increasing the pump load, set the flexure or expansion joint.

C. as far as possible to avoid metal fittings, and plastic piping construction.

Model and parameter

Model

Maximum output

Motor power (kw)

Rotation speed (r/min)

Diameter of inlet and outlet (mm)

Voltage

Flow (m3 /h)  

Head (m)

Imports

Export

(V)

40ZXCW-0.75

15

12

0.75

2900

50

40

380

40ZXCW-1.5

20

15

1.5

2900

50

40

380

40ZXCW-2.2

25

18

2.2

2900

50

40

380

50ZXCW-3

30

20

3

2900

65

50

380

50ZXCW-4

35

22

4

2900

65

50

380

65ZXCW-5.5

40

24

5.5

2900

80

65

380

65ZXCW-7.5

50

28

7.5

2900

80

65

380

100ZXCW-11

90

28

11

2900

100

100

380

100ZXCW-15

120

30

15

2900

100

100

380

100ZXCW-18.5

140

35

18.5

2900

100

100

380

125ZXCW-22

180

35

22

2900

125

125

380

125ZXCW-30

200

40

30

2900

125

125

380

 

Product real shot

 

 

 

 

 

Quality Assurance

Product Inquiry